Overview
Force Repeatability Part to Part < 4% log10(time) Long Term Drift at 1kg for 35 days < 3% log10(time) The specifications are derived from average measurements taken at 5000 grams and are given as (one standard deviation/mean), unless otherwise noted. Measurement is dependent on actuation interface, mechanics, and measurement electronics. The test was performed using FSR UXTM 402 design.